White papersKerem Algüzey, design engineer at ENKA Insaat ve Sanayi A.S., used AFT Fathom to simulate the central heating cycle to inform the design of the hydraulic thermal system for the Dradenau Combined Heat and Power Plant under construction in Hamburg, Germany. This state-of-the-art facility will produce 180 MW of electrical capacity and an additional 260 MW of district heating utilizing multiple heat sources including waste heat from industrial processes and a natural gas power plant. AFT Fathom was used to size pumps, heat exchangers, and control valves, and to validate line sizing to ensure that piping was within design requirements for the system.
White papersUpgrading to Design Envelope pumps helped GAC save energy costs of 20,000 AED in the first year. Armstrong’s Pump Manager service provides reports and notifications to ensure the pumps are optimized. Exemplifying their commitment to sustainability, GAC invested in an HVAC upgrade to reduce energy use.
White paperSubmersible Pump Monitoring Chesterton Connect™ System Solves Pump Maintenance Challenges in the Wastewater Industry [Ebook]
White papersChesterton Connect System Detected Vibration Caused by Ragging Issues in Submersible Pumps Helping Prevent Pump Damage Sewage treatment is a type of wastewater treatment which aims to remove contaminants from sewage to produce an effluent that is suitable to discharge to the surrounding environment or an intended reuse application, thereby preventing water pollution from raw sewage discharges. An increasing maintenance challenge faced by the wastewater industry is the clogging of pipes and pumps in the collection systems and headworks of the sewage treatment process. One contributing factor has been the widespread use of “flushable” wipes and other non-flushable materials, causing significant ragging problems in wet wells and incurring substantial repair costs. Waste from non-flushable materials causes clogs and ragging problem in pipes and pumps. Check out the Submersible Pump & Wastewater Application Webinar available on Chesterton University. Join experts Ryan Zepp and Paul Keough for an in-depth training session on submersible pump applications. Learn to navigate the challenges of “ragging issues” and how the Chesterton Connect System can detect vibrations to prevent pump damage. This detailed training will arm you with the knowledge to confidently sell the value of innovative solutions in pump technology. Elevate your expertise and protect your pumps. Sign up today to access Chesterton University for free: https://chestertonuniversity.com/

White papersIt seems leaf blowers are everywhere in our neighborhoods, very often disturbingly noisy. There is a need for excellent aerodynamic and aeroacoustics design for such devices. Three leaf blower configurations were designed using CFturbo: a single-stage design, a dual-stage design, and a contra-rotating design. The goal of the design study is to minimize the rotational speed required to meet the performance targets and minimize the swirl downstream of the nozzle. The design point volume flow rate was set to 500 cfm at 25,000 rpm with a total pressure difference of 3,000 Pascals. Although the relationship between sound output and rotational speed is not directly proportional, higher rotational speeds often result in remarkably increased noise levels due to higher airflow velocity, higher blade tip speeds, higher frequency noise components, and increased flow instabilities. A robust acoustic design optimization would require extensive simulation and testing. By reducing the downstream swirl, the user has improved directional control over the airflow leaving the device.
White paperSplit Seal + SpiralTrac® Solution Reduces Maintenance and Water Use
White papersA wastewater treatment facility has 10 RAS (Return Activated Sludge) solids handling pumps. These pumps have been sealed using packing and replacement sleeves for several years with major leakage and premature sleeve wear (due to packing abrasion). The customer was looking for an easy way to install solution that would increase Mean Time Between Failure (MTBF) and reduce downtime/repair costs.
White papersThe Study This field survey was conducted at Hormel Foods, Freemont, Nebraska. Voltage readings were taken from the shafts of VFD-driven motors throughout the plant to demonstrate the presence of harmful shaft currents. In addition, voltage readings were taken on the motor that powers the plant’s hog kill main chain drive — both before and after the application of AEGIS® Shaft Grounding Ring technology.
White papersMilk is the basic ingredient in the production of a long list of dairy products and by-products ranging from whole pasteurized milk to cheese, to derivatives such as whey, agglomerated milk and high protein powders, infant formula, whey product concentrate, whey permeate, lactose, and coffee whiteners. And every step in the production of dairy products — from collecting raw milk to transporting, processing, packaging, and storing milk and milk products — requires precise control of process variables such as temperature, flow rates, pressure, line speed, etc. By precisely controlling the speed and torque of motors, VFDs provide cost-effective control of these key process variables.
White papersTwo easily overlooked, yet extremely critical parameters when evaluating and specifying torque transducers are – Mechanical Overload Rating and Electrical Overrange. Each is important, but often confused and misunderstood. Overload – represents a mechanical safety factor for the sensor element. Normally expressed as a percentage of the sensor full scale rating, it is the maximum load limit of the sensor before yield or physical deformation.
White papersIf you’re uncertain about the correct application of Durlon Joint Sealant during installation, we’ve got you covered with these 5 easy steps. Enhance your installation process by downloading Durlon’s Joint Sealant installation this guide.
White papersRobust Motor Design Submersible motors are designed for a wide range of applications, such as deep well water supply, irrigation and pressure boosting. To have a robust insulation system, the insulation shall be designed to withstand the peak voltage levels during operation. Many applications require a long cable between the motor and power supply. Long cables increase the peak voltage level when the motor is driven by a Variable Frequency Drive (VFD), also known as a frequency converter. The primary components of a motor insulation system shall withstand the following voltages: Phase-to-phase, phase-to-ground and turn-to-turn voltages.
White papersAt the Pacific Container Terminal in Long Beach, California, huge cranes lift boxcar-sized containers, arranging them neatly on trains, trucks, and the decks of ships. If the cranes are not working, the whole process shudders to a halt. SSA Marine, owner of the cranes, is just emerging from an ordeal. For years, every one of the company’s 10 cranes, each capable of lifting 50 tons, was plagued with chronic bearing damage. But Reed Electric & Field Service, a Los Angeles motor repair plant, has finally found the cure — the AEGIS® PRO Series Shaft Grounding Ring manufactured by Electro Static Technology.
White papersAlong with solar power, wind power is the fastest growing source of renewable energy. However, inverter-induced voltage can damage the bearings of wind power generators and lead to downtime. One solution to this problem is using AEGIS® Shaft Grounding Rings to reliably prevent such damage through effective grounding.